CALIBRATION OF RHENIUM MOLYBDENUM AND RHENIUM-TUNGSTEN THERMO-COUPLES TO 3200 F

Technical Report ·
OSTI ID:4796743

>Calibration curves for rhenium -molybdenum and rhenium --tungsten thermocouples are presented for temperature measurements to 3200 deg F. Practical applications are discussed as well as advantages and limitations of these elements. (auth)