CORE I CONTROL ROD DRIVE MECHANISM PERIODIC TEST. CORE I, SEED 2. Test Evaluation (T-550011-E). Section 1

Technical Report ·
OSTI ID:4795342

Tests were carried out to determine the operating condition of the rod drive mechanisms so that operating personnel may be informed about any malfunctioning mechanisms. The scram times measured during this test varied from a maximum of 1.138 sec to a minimum of 1.032 sec. No noticeable difference in the scram times from the effects of reactor coolant temperature, reactor coolant pressure, controlling rod group or core location were observed. The effects of the reactor coolant flow, purification service, and total rod motion were observed. (M.C.G.)

Research Organization:
Duquesne Light Co., Shippingport, Penna.
NSA Number:
NSA-16-009631
OSTI ID:
4795342
Report Number(s):
DLCS-1480116
Country of Publication:
United States
Language:
English