Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

PRIMARY PLANT SELF-ACTUATED RELIEF VALVE OPERTION. CORE I, SEED 3. Test Evaluation. Section 1

Technical Report ·
DOI:https://doi.org/10.2172/4795314· OSTI ID:4795314
Tests were carried out on the self-actuated reactor relief valves and the self-actuated pressurizer steam relief valves in order to insure their reliable operation. The valves operated properly, and the final set pressures were all within the specified limits. (D.L.C.)
Research Organization:
Duquesne Light Co., Shippingport, Penna.
Sponsoring Organization:
US Atomic Energy Commission (AEC)
NSA Number:
NSA-16-009633
OSTI ID:
4795314
Report Number(s):
DLCS-3070103
Country of Publication:
United States
Language:
English