PRIMARY PLANT SELF-ACTUATED RELIEF VALVE OPERATION. CORE I, SEED 1. Test Results T-641100-B. Section 1
Tests were made to insure the reliable operation of the self-actuated pressurized steam relief valves and the selfactuated reactor water relief valves within the prescribed pressure settings. Of the six valves tested, four operated within the prescribed operating pressure limitations. Since the actual popping pressure of the other two valves was close to the prescribed operating pressure limitation, no adjustments were made. (W.L.H.)
- Research Organization:
- Duquesne Light Co., Shippingport, Penna.
- Sponsoring Organization:
- US Atomic Energy Commission (AEC)
- NSA Number:
- NSA-15-010513
- OSTI ID:
- 4094916
- Report Number(s):
- DLCS-3070101
- Country of Publication:
- United States
- Language:
- English