DOSE SENSITIVITY OF GEIGER MULLER COUNTERS FOR X-RAYS AND GAMMA RAYS PART II (in German)

Journal Article · · Atompraxis (West Germany) Incorporated in Kerntechnik
OSTI ID:4794972
The dose sensitivity of Geiger-Muller counters for quantum radiation in relation to quantum energy in the range from 10 kev to 3 Mev was calculated for various wall materials, wall thicknesses, filling gases, and filling pressures. For counters with excess air-equivalent gas fillings and sufficiently high filling pressures, the dose sensitivity, as a function of quantum energy, has a maximum at lower energy levels and a minimum at higher energy levels. Practical measures are given for reducing the energy dependence of dose sensitivity. (auth)
Research Organization:
VEB Vakutronik, Dresden
NSA Number:
NSA-16-030607
OSTI ID:
4794972
Journal Information:
Atompraxis (West Germany) Incorporated in Kerntechnik, Journal Name: Atompraxis (West Germany) Incorporated in Kerntechnik Vol. Vol: 8; ISSN ATPXA
Country of Publication:
Country unknown/Code not available
Language:
German

Similar Records

DOSE SENSITIVITY OF GEIGER-MULLER-COUNTERS FOR X-RAYS AND GAMMA RAYS. PART I
Journal Article · Tue May 01 00:00:00 EDT 1962 · Atompraxis (West Germany) Incorporated in Kerntechnik · OSTI ID:4839028

UNIVERSAL TYPE OF BLOCK FOR A GEIGER-MULLER COUNTER
Journal Article · Wed Dec 31 23:00:00 EST 1958 · Uch. Zap., Rizhsk. Politekhn. Inst. · OSTI ID:4693571

Efficiency of Geiger-Muller Counter; EFICIENCIA DE UN CONTADOR GEIGER-MULLER
Technical Report · Sun May 01 00:00:00 EDT 1960 · OSTI ID:4818156