Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Spark Chamber Track Measuring System

Journal Article · · Review of Scientific Instruments
DOI:https://doi.org/10.1063/1.1717993· OSTI ID:4793404

A system is described for the projection, digitizing, and recording of photographed spark chamber tracks. A SloSyn-driven projector automatically frames the film and projects the tracks on a screen mounted in a precision commercial plotting board. A reticle projector, mounted on the plotting board pen holder, is manually positioned by means of the plotting board drive tapes which also drive the encoders of an accumulating digitizer system. A photoelectric gap counting device can be substituted as an alternate for one of these encoders. The all-transistor digitizer system is equipped with manual switches for labeling of tracks, inserting frame numbers, etc., and has a versatile output format on seven hole paper tape. The paper tape with its track coordinate information is used as the input for computer programs designed to calculate the particle physics evidenced by the track.

Research Organization:
Argonne National Lab., Ill.
Sponsoring Organization:
USDOE
NSA Number:
NSA-16-029167
OSTI ID:
4793404
Journal Information:
Review of Scientific Instruments, Journal Name: Review of Scientific Instruments Journal Issue: 8 Vol. 33; ISSN 0034-6748; ISSN RSINAK
Publisher:
American Institute of Physics (AIP)
Country of Publication:
Country unknown/Code not available
Language:
English

Similar Records

ACCURACY OF TRACK LOCATION IN SPARK CHAMBERS. PART I
Journal Article · Mon May 01 00:00:00 EDT 1961 · Rev. Sci. Instr. · OSTI ID:4065510

A TRACK SPARK CHAMBER
Journal Article · Sun Sep 15 00:00:00 EDT 1963 · Phys. Letters · OSTI ID:4700315

SPARK-CHAMBER LABELING OF TRACKS IN A BUBBLE CHAMBER
Technical Report · Tue May 01 00:00:00 EDT 1962 · OSTI ID:4776717