Metering Research Facility Program: Installation effects on 4-inch (102 mm) gas turbine meters. Topical report, November 1993-August 1994

Technical Report ·
OSTI ID:479139

Installation effects on 4-inch (102 mm) turbine meters were investigated under the Gas Research Institute (GRI) Metering Research Facility (MRF) Program. Turbine meters from different manufacturers were tested in nitrogen at pressures of 30 and 115 psia (0.21 and 0,79 MPa) and 10 flowrates from 6.6 to 100 percent of volumetric flow capacity. The Reynolds number (Red) range for the experiments was 16,000 to 950,000. After baseline calibrations, tests were conducted for the short-coupled installation as depicted by Figure 2 of American Gas Association (A.G.A.) Report No. 7, `Shorter Installations for Gas Turbine Meters.`

Research Organization:
Southwest Research Inst., San Antonio, TX (United States)
OSTI ID:
479139
Report Number(s):
PB--97-151450/XAB; CNN: Contract GRI-5086-271-2197
Country of Publication:
United States
Language:
English