MEASUREMENT OF SAFETY ROD DROP TIMES AT THE LPTR

Technical Report ·
OSTI ID:4789351
A sensor for measuring LPTR rod drop time is described which consists of a filter coil rated at 10h affixed to a split tube sized to fit around the outside of an LPTR magnet guide tube. When a measurement is desired, the device is lowered over the guide tube and seated on top of the core with the coil in a horizontal plan corresponding to the fully inserted limit of the soft-iron armature on the safety rod. The coil assembly is connected to an oscilloscope which is then triggered by any signal which can initiate a rod drop. By observing the oscilloscope, rod drop measurements can be made. (J.R.D.)
Research Organization:
California. Univ., Livermore. Lawrence Radiation Lab.
DOE Contract Number:
W-7405-ENG-48
NSA Number:
NSA-16-031329
OSTI ID:
4789351
Report Number(s):
UCRL-6348
Country of Publication:
United States
Language:
English

Similar Records

MAGNETIC COIL TELLS WHEN CONTROL ROD SEATS
Journal Article · Wed Feb 28 23:00:00 EST 1962 · Nucleonics (U.S.) Ceased publication · OSTI ID:4810445

ELECTROMAGNETIC DISPLACING MEANS FOR NEUTRON ABSORBING CONTROL RODS
Patent · Wed Dec 28 23:00:00 EST 1960 · OSTI ID:4107626

THE LIVERMORE POOL TYPE REACTOR (LPTR)