LOW-LEVEL TRITUM MEASUREMENT WITH THE LIQUID SCINTILLATION SPECTROMETER. Progress Report No. 1

Technical Report ·
OSTI ID:4786915
The practical application of tritium to engineering problems involving water tracing is dependent on the availability of a highly sensitive yet economical method of tritium measurement. The liquid scintillation spectrometer affords a methodology for tritiated water detection at concentrations of 10-6 mu c/ml or less, and is believed to be generally superior to ion chamber or proportional type counters. Detection sensitivity was defined as the quantity of liquid that can be labeled with a unit of radioactivity and subsequently detected with a confidence level of approximately 95 per cent. Detection sensitivity may be expressed formally as a function of counter efflciency, sample volume, background, and counting time. Using a 30-min counting period, sensitivities in excess of 1800 1/ mu c were obtained wdth a scintillator comprised of dioxane, naphthalene, PPO, POPOP, and water. Scintillator volumes of over 200 ml were employed with the scintillator in direct optical contact with the photomultiplier tubes of a coincidence type spectrometer. Specifications of an insert cell for use with a commercial liquid scintillation spectrometer are given. The insert cell makes possible detection sensi-tivities of over 1000 1/ mu c. A comparison was made of the sensitivities of the single photomultiplier spectrometer and the two-photomultiplier coincidence spectrometer. It was concluded that the two systems can be operated with nearly comparable sensitivities, but for low-level measurements the latter system has the advantage of a more stable background with a lesser liability to thermionic and light-induced phosphorescence disturbances. (auth)
Research Organization:
California. Univ., Berkeley. Sanitary Engineering Research Lab; and CAlifornia. Univ., Berkeley. School of Public Health
DOE Contract Number:
AT(11-1)-34
NSA Number:
NSA-16-012959
OSTI ID:
4786915
Report Number(s):
TID-13910
Country of Publication:
United States
Language:
English

Similar Records

TRITIUM COUNTING IN LIQUID SCINTILLATORS WITH P-OLIGOPHENYLS
Journal Article · Mon Dec 31 23:00:00 EST 1962 · Radiochimica Acta (West Germany) · OSTI ID:4702161

A METHOD FOR ROUTINE DETERMINATIONS OF TRITIUM IN URINE USING A COINCIDENCE LIQUID SCINTILLATION COUNTER
Technical Report · Thu Jun 01 00:00:00 EDT 1961 · OSTI ID:4842989

A TRITIUM COUNTER DESIGNED FOR ROUTINE LABORATORY USE
Journal Article · Thu Dec 31 23:00:00 EST 1959 · Phys. in Med. Biol. · OSTI ID:4181577