Shielding Calculations for the DIDO Materials Testing Reactor; ABSCHIRMUNGSBERECHNUNG FUR DEN MATERIAL-PRUFREAKTOR DIDO

Technical Report ·
OSTI ID:4778063
Shielding calculations are presented along with the results for the 10- Mw DIDO Materials Testing Reactor at Julich, Germany. The dosage outside the reactor shielding is approximately 0.73 mrem/hr at its weakest place. The calculations are broken down into the neutron fluxes for different power rates and for the different concrete compositions with respect to gamma capture. (N.W.R.)