skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Measuring depth profiles of residual stress with Raman spectroscopy

Technical Report ·
DOI:https://doi.org/10.2172/476628· OSTI ID:476628

Knowledge of the variation of residual stress is a very important factor in understanding the properties of machined surfaces. The nature of the residual stress can determine a part`s susceptibility to wear deformation, and cracking. Raman spectroscopy is known to be a very useful technique for measuring residual stress in many materials. These measurements are routinely made with a lateral resolution of 1{mu}m and an accuracy of 0.1 kbar. The variation of stress with depth; however, has not received much attention in the past. A novel technique has been developed that allows quantitative measurement of the variation of the residual stress with depth with an accuracy of 10nm in the z direction. Qualitative techniques for determining whether the stress is varying with depth are presented. It is also demonstrated that when the stress is changing over the volume sampled, errors can be introduced if the variation of the stress with depth is ignored. Computer aided data analysis is used to determine the depth dependence of the residual stress.

Research Organization:
Los Alamos National Lab. (LANL), Los Alamos, NM (United States); North Carolina State Univ., Raleigh, NC (United States)
OSTI ID:
476628
Report Number(s):
LA-SUB-93-81; ON: DE97003578; TRN: 97:002288-0004
Resource Relation:
Other Information: PBD: Dec 1988; Related Information: Is Part Of Precision Engineering Center. 1988 Annual report, Volume VI; Dow, T. [ed.]; Fornaro, R.; Keltie, R.; Paesler, M. [and others]; PB: 367 p.
Country of Publication:
United States
Language:
English