EXPERIMENTAL PERSONNEL RADIATION DOSIMETERS
Technical Report
·
OSTI ID:4748399
Two experimental pocket-size radiation dosimeters were developed to provide either an indicated measurement of accumulated dose or suitable alarming for preselected dose levels. One audibly alarms after a predetermined dose is accumulated. The second provides digital indication of the received dose on a miniature register. Both are adaptable to radiotelemetry methods of information transfer. The dosimeter which alarms has a dose range of 0 -200 mr; however, with different sensors, this range can be extended up to 0--600 r. The sensor is a pencil ionization chamber modified to include an illuminated quartz fiber, an optical system, and a CdS light detector. By proper chamber charging, the unit can be adjusted to provide a suitable signal from the CdS cell after the predetermined dose is exceeded. The cell signal drives transistorized circuitry for alarming, and a second light sensor is included for temperature compensation. For the 0 --200 mr ionization chamber, the alarm can be adjusted for any point from 10 mr to 200 mr. The accumulated dose can be read out at any time with a standard charger-reader. The second dosimeter uses a pencil ionization chamber sensor, modified with a quartz rod and fiber to permit automatic recharging. A pulse produced for each recharge cycle is used with transistorized circuitry to drive an incorporated miniature electromechanical register. Completed tests show that each register digit is equivalent to an accumulated dose of about 8 mr over a tested dose-rate range from 10 mr/hr to 4 r/hr. A capacitor voltage supply is used for the pencil dosimeter and the supply can be recharged with a standard pencil charger. Either experimental dosimeter will operate approximately 50 hours on one set of batteries. (auth)
- Research Organization:
- General Electric Co. Hanford Atomic Products Operation, Richland, Wash.
- DOE Contract Number:
- AT(45-1)-1350
- NSA Number:
- NSA-16-033310
- OSTI ID:
- 4748399
- Report Number(s):
- HW-SA-2590
- Country of Publication:
- United States
- Language:
- English
Similar Records
A TRANSISTORIZED POCKET RADIATION DOSIMETER WITH AURAL ALARM
Smart Radiological Dosimeter
THE POCKET DOSIMETER
Technical Report
·
Fri Sep 15 00:00:00 EDT 1961
·
OSTI ID:4640735
Smart Radiological Dosimeter
Patent
·
Tue Jul 20 00:00:00 EDT 2004
·
OSTI ID:827824
THE POCKET DOSIMETER
Journal Article
·
Thu Nov 30 23:00:00 EST 1961
· Ann. Occupational Hyg.
·
OSTI ID:4731720
Related Subjects
BATTERIES
CADMIUM SULFIDES
CAPACITORS
CIRCUITS
CONFIGURATION
DETECTION
DIGITAL SYSTEMS
DOSEMETERS
ELECTRIC CHARGES
ELECTRIC PROBES
ELECTRICITY
ELECTRONIC EQUIPMENT
FIBERS
HEALTH AND SAFETY
IONIZATION CHAMBERS
LIGHT
MEASURED VALUES
MONITORING
OPERATION
OPTICAL SYSTEMS
PERSONNEL
PHOTOELECTRIC CELLS
PULSES
QUANTITY RATIO
QUARTZ
RADIATION DOSES
REMOTE CONTROL
RODS
SENSITIVITY
SIGNALS
STANDARDS
TEMPERATURE
TRANSISTORS
USES
CADMIUM SULFIDES
CAPACITORS
CIRCUITS
CONFIGURATION
DETECTION
DIGITAL SYSTEMS
DOSEMETERS
ELECTRIC CHARGES
ELECTRIC PROBES
ELECTRICITY
ELECTRONIC EQUIPMENT
FIBERS
HEALTH AND SAFETY
IONIZATION CHAMBERS
LIGHT
MEASURED VALUES
MONITORING
OPERATION
OPTICAL SYSTEMS
PERSONNEL
PHOTOELECTRIC CELLS
PULSES
QUANTITY RATIO
QUARTZ
RADIATION DOSES
REMOTE CONTROL
RODS
SENSITIVITY
SIGNALS
STANDARDS
TEMPERATURE
TRANSISTORS
USES