Magnet regulators for ORIC

Journal Article · · Nuclear Instruments and Methods
Twenty-one current regulator systems were built, tested, and put in operation in the Oak Ridge Isochronous Cyclotron. Two motor-generator units rated at 800 and 1200 kw are regulated by transistor banks in the field circuits of the generators. Nineteen other magnet supplies are rectifier-magnetic amplifier systems with ratings ranging from 6 to 50 kw at25) to 1200 A; for regulation these incorporate transistor banks in series with the load. All units are current regulated to a few parts in 105; the transistor banks also reduce the ripple voltage of the rectifier units. By means of single controls all units can be varied from 2 to 100% of rated output current. Design features and selection of components for these systems are discussed. Design of the large banks of paralleled transistors used and experience in their operation are also reported.
Research Organization:
Oak Ridge National Lab., Tenn.
Sponsoring Organization:
USDOE
NSA Number:
NSA-17-007376
OSTI ID:
4746990
Journal Information:
Nuclear Instruments and Methods, Journal Name: Nuclear Instruments and Methods Journal Issue: C Vol. 18-19; ISSN 0029-554X
Publisher:
Elsevier
Country of Publication:
Country unknown/Code not available
Language:
English

Similar Records

High-Currrent Regulated Supply, Combining Transistors and Magnetic Amplifiers, for the Oak Ridge Isochronous Cyclotron
Journal Article · Sun Oct 01 00:00:00 EDT 1961 · IRE Transactions on Nuclear Science · OSTI ID:4833455

Design and develop speed/pressure regulator
Technical Report · Wed Sep 01 00:00:00 EDT 1993 · OSTI ID:10181918

TRANSISTORIZED SERIES REGULATOR FOR ANALYZING MAGNET
Journal Article · Wed Jan 31 23:00:00 EST 1962 · Rev. Sci. Instr. · OSTI ID:4802990