Pressure transducer evaluation report
Book
·
OSTI ID:4740811
Performance evaluation of 17 unbonded strain gage transducers was conducted to determine the suitability of these models to measure air pressures in an air cycle reactor system. The requirement was a maximum of plus or minus 2% error for 50 hours of continuous operation with an operating temperature of 150 to 250 deg F and a maximum vibration of 5 g. The results indicate that this type of transducer will perform satisfactorily. (D.L.C.)