XENON POISONING IN A SHUT-DOWN REACTOR

Journal Article · · Nuclear Science and Engineering (U.S.)
OSTI ID:4718667

The method of calculating an effective flux for the whole reactor was used to calculate the xenon buildup and decay after shutdown. A xenon run was made in the Diorit reactor, in which xenon was first allowed to build up at a power of 17.6 Mw and the power then reduced to 0.16 Mw. The measured reactivity invested in xenon was in good agreement with the theoretical predictions. (D.L.C.)

Research Organization:
Federal Inst. for Reactor Research, Wurenlingen, Switzerland
NSA Number:
NSA-17-026812
OSTI ID:
4718667
Journal Information:
Nuclear Science and Engineering (U.S.), Journal Name: Nuclear Science and Engineering (U.S.) Vol. Vol: 15; ISSN NSENA
Country of Publication:
Country unknown/Code not available
Language:
English

Similar Records

THEORETICAL AND EXPERIMENTAL STUDY ON REACTIVITY CHANGE IN REACTORS, CAUSED BY XENON POISONING
Journal Article · Mon Dec 31 23:00:00 EST 1962 · Zeitschrift fuer Angewandte Mathematik und Physik (Switzerland) · OSTI ID:4681866

Effective Xenon Poisoning After Shut-Down of a Thermal Reactor
Journal Article · Thu Nov 30 23:00:00 EST 1961 · Kernenergie (Berlin) · OSTI ID:4792222

On Xenon Fission Product Poisoning
Conference · Mon Sep 23 00:00:00 EDT 2019 · OSTI ID:1635366