A study was performed to determine if the coolant outlet temperature would exceed the 1150 un. Concent 85% F limitation during a loss of plant power without forced cooling. Results indicate a scram on loss-of-power should be included in the EGCR safety to prevent excessive outlet temperatures in such an occurrence. (auth)