AN ACHROMATIC TRANSLATION SYSTEM FOR CHARGED PARTICLE BEAMS

Technical Report ·
DOI:https://doi.org/10.2172/4699840· OSTI ID:4699840
An assembly of bending magnets and magnetic quadrupole lenses was found which causes the axis of a beam of charged particles of momenta p plus or minus DELTA p to be shifted from its original axis to a parallel line displaced from its original axis by a distance d. A study of this transport system demonstrated that it is possible to choose the parameters of the system in such a way that the entire system has an acceptable effect on the transverse motion of the beam, and so that the system is achromatic to first order in DELTA p/p. A typical transport system is given, and results are presented in graphical form for a range of parameters encompassing the typical values. (auth)
Research Organization:
Midwestern Universities Research Assn., Madison, Wis.
Sponsoring Organization:
USDOE
NSA Number:
NSA-17-031274
OSTI ID:
4699840
Report Number(s):
CONF-46-38
Country of Publication:
United States
Language:
English

Similar Records

Achromat Design for Multi-Pulse Test Line
Technical Report · Wed Feb 09 23:00:00 EST 2022 · OSTI ID:1846874

Beam deflection into a quadrant by a positionally stationary magnetic bending system
Technical Report · Fri Jun 20 00:00:00 EDT 1980 · OSTI ID:5215373

An analytical study of double bend achromat lattice