TAKING HUMAN ERROR OUT OF NUCLEAR EXPERIMENTS
Journal Article
·
· Electronics (U.S.)
OSTI ID:4697023
A programmable preset timer is described for the automatic operation of an experiment of several runs with setup and active times. The timer includes a multiple preset six-decade counter with binary coded decimal outputs and a seven- level paper-tape reader-programmer. (D.L.C.)