SODIUM RESISTIVITY METER LOOP. Summary Report, May 1963

Technical Report ·
OSTI ID:4674585
Work has progressed on the rhometer temperature compensator to the point of successful operation at 900 deg F. Two commercial, multiple-winding transformers were introduced to extend the incremental range of existing transformers. The new auxiliary transformers couple the voltage across the platinum temperature compensator resistance and the zero coefficient resistance into the signal summation loop of the original meter circuit. C pensation to 1000 deg F can be attained with only two ratio changes in transformers A and B, or three set points in all, including the original circuit, or O set point. (N.W.R.)