SODIUM RESISTIVITY METER LOOP. Summary Report, December 1963
Technical Report
·
OSTI ID:4106192
A series of experiments for the evaluation and improvement of several in- line meters designed to determine the contamination level of various impurities in a controlled sodium loop were completed. The performance and contamination of the loop cold trap, line sections, rhometer, and variable-orifice plugging meter were evaluated. Recalibration of the rhometer and plugging meter for sodium hydride contamination by hydrogen gas injection procedures was made. (N.W.R.)
- Research Organization:
- Atomic Power Development Associates, Inc., Detroit Page(s): 9
- NSA Number:
- NSA-18-010345
- OSTI ID:
- 4106192
- Report Number(s):
- TID-20126
- Country of Publication:
- United States
- Language:
- English
Similar Records
OPERATION OF THE SODIUM TECHNOLOGY LOOP FOR CONTAMINATION METER EVALUATIONS
SODIUM RESISTIVITY METER LOOP. Summary Report, July 1963
SODIUM RESISTIVITY METER LOOP. Summary Report, June 1963
Technical Report
·
Tue Mar 24 23:00:00 EST 1964
·
OSTI ID:4054242
SODIUM RESISTIVITY METER LOOP. Summary Report, July 1963
Technical Report
·
Wed Oct 30 23:00:00 EST 1963
·
OSTI ID:4654501
SODIUM RESISTIVITY METER LOOP. Summary Report, June 1963
Technical Report
·
Wed Oct 30 23:00:00 EST 1963
·
OSTI ID:4683132