SODIUM RESISTIVITY METER LOOP. Summary Report, December 1963

Technical Report ·
OSTI ID:4106192
A series of experiments for the evaluation and improvement of several in- line meters designed to determine the contamination level of various impurities in a controlled sodium loop were completed. The performance and contamination of the loop cold trap, line sections, rhometer, and variable-orifice plugging meter were evaluated. Recalibration of the rhometer and plugging meter for sodium hydride contamination by hydrogen gas injection procedures was made. (N.W.R.)
Research Organization:
Atomic Power Development Associates, Inc., Detroit Page(s): 9