AMPLITUDE-TIME DISCRIMINATION OF GAMMA-RAY BACKGROUND IN A FAST NEUTRON SCINTILLATION SPECTROMETER (in Russian)

Journal Article · · Izvestiya Akademii Nauk, Seriya Fizicheskaya (U.S.S.R.) For English translation see Bull. Acad. Sci. USSR, Phys. Ser. (Engl. Transl.)
OSTI ID:4653982
An apparatus, which utilizes araplitude-time discrimination to separate out gamma background from fast neutrons in a scintillation spectrometer, is described. The electronics portion of the resolution system is shown in a block diagram. It consists of a resolving circuit, a resolution channel, a time-delay channel, and a coincidence circuit. The operation of the resolution system is illustrated by an oscillograph display which shows the separation of neutron and gamma pulses resulting from a Po-Be source. The resolution and scintillation spectrometer thresholds of the system were found to be 20 and 80 kev, respectively. The resolution apparatus was found to operate well as long as the integral load did not exceed 4000 pulses/sec. (TTT)
Research Organization:
Originating Research Org. not identified
NSA Number:
NSA-17-039433
OSTI ID:
4653982
Journal Information:
Izvestiya Akademii Nauk, Seriya Fizicheskaya (U.S.S.R.) For English translation see Bull. Acad. Sci. USSR, Phys. Ser. (Engl. Transl.), Journal Name: Izvestiya Akademii Nauk, Seriya Fizicheskaya (U.S.S.R.) For English translation see Bull. Acad. Sci. USSR, Phys. Ser. (Engl. Transl.) Vol. Vol: 27; ISSN IANFA
Country of Publication:
Country unknown/Code not available
Language:
Russian