DECONTAMINATION EXPERIENCE WITH HIGH-TEMPERATURE IN-REACTOR TEST LOOPS

Technical Report ·
OSTI ID:4629434
The Hanford KER-2, 3, and 4 Loops were decontaminated successfully with the following process: (1) organic filmconditioning solution, (2) nitric acid neutralizing rinse, (3) alkaline permanganate solution, (4) water rinses, (5) nitric acid solution, and (6) water rinses. Radioactivity levels before and after decontamination are given for various loop locations. The process was modified to reduce the reactor down-time: (1) alkaline permanganate solution, (2) water rinses, (3) acidic rinse, and (4) water rinses. The KER-2 Loop was decontaminated successfully using this modified process with a bisulfate and a suifamate acidic rinse. Precautions to be taken in the decontamination are described. (D.L.C.)
Research Organization:
General Electric Co. Hanford Atomic Products Operation, Richland, Wash.
DOE Contract Number:
AT(45-1)-1350
NSA Number:
NSA-17-038434
OSTI ID:
4629434
Report Number(s):
HW-SA-3021; CONF-102-5
Country of Publication:
United States
Language:
English

Similar Records

DECONTAMINATION OF THE IRRADIATED RUPTURE PROTOTYPE WITH PEROXIDE-CARBONATE AND APACE
Technical Report · Tue Jan 12 23:00:00 EST 1960 · OSTI ID:4193021

DECONTAMINATION OF THE E-20 LOOP IN NRU
Journal Article · Mon Dec 31 23:00:00 EST 1962 · Can. Nucl. Tech. · OSTI ID:4719122

DECONTAMINATION OF PRESSURIZED-WATER SYSTEMS. (thesis)
Technical Report · Sun Dec 31 23:00:00 EST 1961 · OSTI ID:4817422