Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Reducing the effect of nonstationary resolution on activity quantitation with the frequency distance relationship in SPECT

Journal Article · · IEEE Transactions on Nuclear Science
DOI:https://doi.org/10.1109/23.552748· OSTI ID:458242
 [1]; ; ; ;  [1]
  1. Univ. of Massachusetts Medical Center, Worcester, MA (United States). Dept. of Nuclear Medicine

The determination of quantitative estimates of activity such as the maximum and total counts in a volume are influenced by the partial volume effect. The magnitude of this effect varies with the nonstationary spatial resolution inherent in SPECT imaging, the size and shape of the object, and the relative concentration of the object to its background. The objective of this investigation was to determine if frequency distance relationship (FDR) restoration filtering can reduce the impact of distance-dependent spatial resolution on the quantitation of activity. An analytical projector was used to incorporate attenuation and distance-dependent blurring when simulating a set of small hot spherical objects in a cylindrical attenuator. Reconstruction was performed by filtered backprojection (FBP) with Bellini`s method of attenuation correction. The simulations were filtered by: (1) three-dimensional (3-D) Butterworth filtering; (2) stationary parametric Wiener filtering; and (3) FDR restoration filtering regularized using Gaussian and parametric Wiener filters. The criteria used to compare the accuracy of quantitation were the center count ratios (CCR`s) and total count ratios (TCR`s). Both were determined as the ratio of observed counts over true counts. Results showed that after FDR restoration the TCR`s varied less with location, and for both CCR`s and TCR`s the bias decreased compared to Butterworth filtering.

Sponsoring Organization:
National Cancer Inst., Bethesda, MD (United States)
OSTI ID:
458242
Report Number(s):
CONF-951073--
Journal Information:
IEEE Transactions on Nuclear Science, Journal Name: IEEE Transactions on Nuclear Science Journal Issue: 6Pt2 Vol. 43; ISSN 0018-9499; ISSN IETNAE
Country of Publication:
United States
Language:
English

Similar Records

Distance-dependent restoration filtering of dual photopeak window scatter compensated SPECT images
Conference · Wed Nov 30 23:00:00 EST 1994 · IEEE Transactions on Nuclear Science (Institute of Electrical and Electronics Engineers); (United States) · OSTI ID:6700270

Attenuation correction strategies for multi-energy photon emitters using SPECT
Conference · Mon Dec 30 23:00:00 EST 1996 · OSTI ID:513244

Filtering of SPECT reconstructions made using Bellini's attenuation correction method; A comparison of three pre-reconstruction filters and a post-reconstruction Wiener filter
Journal Article · Sun Mar 31 23:00:00 EST 1991 · IEEE Transactions on Nuclear Science (Institute of Electrical and Electronics Engineers); (United States) · OSTI ID:5076219