Metering Research Facility Program: Pressure and calibration effects on 12-inch gas turbine flow meters. Technical memorandum, June 1995-February 1996
Technical Report
·
OSTI ID:445826
The testing of 12-inch turbine meters in the MRF-HPL was intended to obtain independent data on how well commonly used turbine meters perform when calibrated and used on natural gas at typical pipeline operating pressures. The effects of different pressures, Reynolds numbers, and apparent drag were investigated. In accordance with the objectives, these tests have verified that the in-service repeatability and reproducibility of three typical 12-inch turbine meter, when used with high pressure natural gas, are better than the industry standard accuracy (plus or minus 1.0%).
- Research Organization:
- Southwest Research Inst., San Antonio, TX (United States)
- OSTI ID:
- 445826
- Report Number(s):
- PB--97-129316/XAB; CNN: Contract GRI-5095-271-3363
- Country of Publication:
- United States
- Language:
- English
Similar Records
Metering Research Facility Program. Orifice meter installation effects: Ten-inch sliding flow conditioner tests. Technical memorandum, January-June 1996
Metering Research Facility Program: Performance tests of 12-inch multipath ultrasonic flow meters. Topical report, October 1994-March 1996
Metering Research Facility Program: Installation effects on 4-inch (102 mm) gas turbine meters. Topical report, November 1993-August 1994
Technical Report
·
Thu Oct 31 23:00:00 EST 1996
·
OSTI ID:445825
Metering Research Facility Program: Performance tests of 12-inch multipath ultrasonic flow meters. Topical report, October 1994-March 1996
Technical Report
·
Thu Aug 01 00:00:00 EDT 1996
·
OSTI ID:406031
Metering Research Facility Program: Installation effects on 4-inch (102 mm) gas turbine meters. Topical report, November 1993-August 1994
Technical Report
·
Mon Aug 01 00:00:00 EDT 1994
·
OSTI ID:479139