Comparison of oxygen determination methods for Ta--10W alloy
Technical Report
·
OSTI ID:4425843
The relative merits of present analytical methods for the determination of oxygen in tantalum alloys were evaluated at Mound Laboratory. Standards were prepared by doping Ta-- 10 wt% W alloy with approximately 200, 400, 600, and 1000 mu g of oxygen per gram of metal. Methods evaluated included: inertgas fusion using induction heating; inert-gas fusion using high amperage current; vacuum fusion; and neutron activation analysis. The inert-gas fusion using high amperage current yielded the best results and the equipment for this method was subsequently modified for use in the analysis of both radioactive and nonradioactive samples. (auth)
- Research Organization:
- Mound Lab., Miamisburg, Ohio (USA)
- DOE Contract Number:
- AT(33-1)-GEN-53
- NSA Number:
- NSA-29-002423
- OSTI ID:
- 4425843
- Report Number(s):
- MLM--2086
- Country of Publication:
- United States
- Language:
- English