Variable reluctance displacement transducer temperature compensated to 650$sup 0$F
Technical Report
·
OSTI ID:4393756
650 deg F. Piper, T. C.; Colson, J. B. (Aerojet Nuclear Co., Idaho Falls, Idaho (USA)). Nov 1973. Contract AT(10-1)-1375. ' 16p. Dep. NTlS 00. A variable reluctnce transducer (VRT) with plus or minus 0.100- inch stroke to operate to 550 deg F is described. Specific design effort was taken to optimize the desiga to have minimum change in the VRT's null and sensitivity with rapid thermal and pressure transients. Null and sensitivity stabilities of plus or minus 0.5% and 1.8% of full scale, respectively, were obtained. Appentice; 'ineate the various effects considered in optimizing the design. (auth)
- Research Organization:
- Aerojet Nuclear Co., Idaho Falls, Idaho (USA)
- DOE Contract Number:
- AT(10-1)-1375
- NSA Number:
- NSA-29-010288
- OSTI ID:
- 4393756
- Report Number(s):
- ANCR-1130
- Resource Relation:
- Other Information: Orig. Receipt Date: 30-JUN-74
- Country of Publication:
- United States
- Language:
- English