The design principles and operational experience for the plants asociated with the control of coolant composition in two of the loop circuits of the Windscale AGR are described. Each plant is capable of independent operation, its function being to oxidize CO and H/sub 2/, aid to remove excess H/sub 2/0. Facilities are also provided for injecting CH/sub 4/, CO and other possible additives. The plants have oper-led satisfactorily and in conjunction with in- core loop circuits provide a facility in which full-size fuel pins for commercial AGRs can be irradiated in a range of coolant environments. (UK)