Benchmark of POWERTRAX CMSS against PWR transient power measurements
Journal Article
·
· Transactions of the American Nuclear Society
OSTI ID:436987
- Carolina Power and Light Co., Raleigh, NC (United States)
- Siemens Power Corp., Richland, WA (United States)
The POWERTRAX{trademark} CMSS (core monitoring software system) was developed and implemented on the Shearon Harris (HNP) and H. B. Robinson (RNP) nuclear plants to monitor in-core technical specifications and provide assistance to operators during various modes of pressurized water reactor (PWR) operations. Currently, a study is being conducted to utilize the capability of POWERTRAX for assisting the power ascension from beginning-of-cycle startup. This paper presents results from a POWERTRAX benchmark against measurements of transient power distributions on the Harris and Robinson reactors.
- OSTI ID:
- 436987
- Report Number(s):
- CONF-9606116--
- Journal Information:
- Transactions of the American Nuclear Society, Journal Name: Transactions of the American Nuclear Society Vol. 74; ISSN 0003-018X; ISSN TANSAO
- Country of Publication:
- United States
- Language:
- English
Similar Records
Water-hammer experiences in the startup and early operation of the Shearon Harris plant
Benchmarking of NESTLE against measured PWR data at beginning of life
Benchmarking of NESTLE against measured PWR data at beginning of life
Conference
·
Wed Dec 31 23:00:00 EST 1986
· Trans. Am. Nucl. Soc.; (United States)
·
OSTI ID:7100677
Benchmarking of NESTLE against measured PWR data at beginning of life
Conference
·
Sat Jul 01 00:00:00 EDT 1995
·
OSTI ID:102190
Benchmarking of NESTLE against measured PWR data at beginning of life
Journal Article
·
Sat Dec 30 23:00:00 EST 1995
· Transactions of the American Nuclear Society
·
OSTI ID:411756