Correction Factors for Measurements with Cadmium Covered Foils

Technical Report ·
DOI:https://doi.org/10.2172/4359571· OSTI ID:4359571
 [1]
  1. North American Aviation, Inc., Downey, CA (United States)
Cadmium- covered foils are frequently used to measure the neutron flux with energy above that represented by the cadmium cut-off point. Correction factors to account for the attenuation of the epicadmium neutrons by the cadmium are given and compared with results by earlier experimenters. In the present work, foil area, foil thickness, and cadmium ratio were varied with no detectible effect on the correction factor. Values are given for both indium and gold, and a further small correction to account for the leak-through of sub-cadmium or thermal neutrons is discussed.
Research Organization:
North American Aviation, Inc., Downey, CA (United States)
Sponsoring Organization:
US Atomic Energy Commission (AEC); USDOE National Nuclear Security Administration (NNSA), Nuclear Criticality Safety Program (NCSP)
DOE Contract Number:
AT(11-1)-GEN-8
NSA Number:
NSA-08-007082
OSTI ID:
4359571
Report Number(s):
NAA-SR--1076
Country of Publication:
United States
Language:
English

Similar Records

Cadmium correction factors of several thermal neutron foil detectors
Journal Article · Sat Sep 01 00:00:00 EDT 1973 · J. Nucl. Energy, v. 27, no. 9, pp. 677-688 · OSTI ID:4422739

THE ABSOLUTE MEASUREMENT OF THERMAL NEUTRON FLUX
Journal Article · Thu Dec 31 23:00:00 EST 1959 · Acad. rep. populare Romine, Inst. fiz. atomica si Inst. fiz. Studii cercetari fiz. · OSTI ID:4168303

CADMIUM RATIO MEASUREMENTS WITH THIN AND THICK GOLD FOILS AND THEIR RELATION TO REACTOR SPECTRA
Journal Article · Thu Dec 31 23:00:00 EST 1959 · J. Nuclear Energy, Pt. A. Reactor Sci. · OSTI ID:4117181