CADMIUM RATIO MEASUREMENTS WITH THIN AND THICK GOLD FOILS AND THEIR RELATION TO REACTOR SPECTRA

Journal Article · · J. Nuclear Energy, Pt. A. Reactor Sci.

A method is given for obtaining corrections to cadmium ratio measurements for flux depressions in the foil and flux perturbation effects in order that the result may be used in descriptions of the reactor neutron-energy spectrum. The effects are accounted for by introducing combined flux-depression and flux-perturbation factors, one for each of the three spectral shapes: (a) h/ sup M/(X) for the Maxwellian flux; (b) h/sup e/(X) for the epithermal flux, E > mu kT; and (c) h/sub cd/(X) for the resonance flux, E > E /sub cd/, where X is the foil thickness. The values of H/sup M/(X) and H/sup e/(X) were determined experimentally with gold foils. These values are given as a function of the foil thickness from 0 to 100 mg/ cm/sup 2/ (B O.G.)

Research Organization:
Danish Atomic Energy Commission Research Establishment, Riso
NSA Number:
NSA-15-007545
OSTI ID:
4117181
Journal Information:
J. Nuclear Energy, Pt. A. Reactor Sci., Journal Name: J. Nuclear Energy, Pt. A. Reactor Sci. Vol. Vol: 12
Country of Publication:
Country unknown/Code not available
Language:
English

Similar Records

Cadmium correction factors of several thermal neutron foil detectors
Journal Article · Sat Sep 01 00:00:00 EDT 1973 · J. Nucl. Energy, v. 27, no. 9, pp. 677-688 · OSTI ID:4422739

MEASURING THE RATIO OF EPI-THERMAL TO THERMAL NEUTRON DENSITIES USING THICK GOLD FOILS
Journal Article · Fri Jul 01 00:00:00 EDT 1960 · J. Atomic Energy Soc. Japan · OSTI ID:4161514

Thickness corrections for neutron-activated gold foils
Thesis/Dissertation · Fri Jan 31 23:00:00 EST 1969 · OSTI ID:4779034