Sodium heated to 600 deg F and flowing initially at 2980 gpm was subjected to water injection at the rate of 0.024 lbs/sec. After about 124 sec the water injection was terminated because of greatly reduced Na flow. After approximately 10 min., a small leak was found in the loop at the point of water injection and the pressure in the loop was relieved by venting off gases. After the leak sealed itself, H/sub 2/ was removed by outgassing and the loop pressure raised to 20 psig by addition of N/sub 2/. When the loop was heated to 653 deg F a few hours later, flow returned to normal. Cold trapping was successfully initially at 500 deg F and eventually down to 300 deg F. A summary of flow, temperature, and pressure data are presented. (L.M.T.)