Results of ORNL measurements made during the International Neutron Dosimetry Intercomparison, March 19--30, 1973
The Radiation Research and Development Section of the Health Physics Division at ORNL participated in the International Dosimetry Intercomparison (INDI) on March 19 through 30, 1973, at the Brookhaven National Laboratory. The intercomparison measurements were made at the Radiological Research Accelerator Facility (RARAF) which is operated by Columbia University. Several laboratories participated; however, only the results of the ORNL group are presented. At the RARAF a 4-MeV Van de Graaff accelerator was used to produce neutrons of several different energies, and a nominal 2-mg californium-252 source was used. The measurements included both neutron and gamma-ray kerma in air for each of the sources and absorbed dose ln a water-filled phantom for 15.4- and 5.55-MeV neutrons. Gamma-ray kerma and absorbed dose rate measurements were made using a Phil'' Geiger counter, and neutron kerma and absorbed dose rates were measured with an in-phantom Hurst proportional counter. Intercomparison data are given and discussed. (WHK)
- Research Organization:
- Oak Ridge National Lab., Tenn. (USA)
- DOE Contract Number:
- W-7405-ENG-26
- NSA Number:
- NSA-29-018435
- OSTI ID:
- 4343553
- Report Number(s):
- ORNL-TM--4441
- Country of Publication:
- United States
- Language:
- English
Similar Records
Nonparametric analysis of an international neutron dosimetry intercomparison
Personnel dosimetry intercomparison studies at the ORNL Health Physics Research Reactor
EXPERIMENTAL STUDIES OF ENERGY RESPONSE OF FAST NEUTRON DETECTORS
Conference
·
Wed Dec 31 23:00:00 EST 1975
·
OSTI ID:7347214
Personnel dosimetry intercomparison studies at the ORNL Health Physics Research Reactor
Conference
·
Fri Dec 31 23:00:00 EST 1976
·
OSTI ID:5196995
EXPERIMENTAL STUDIES OF ENERGY RESPONSE OF FAST NEUTRON DETECTORS
Journal Article
·
Sat Jun 01 00:00:00 EDT 1963
· Oyo Buturi
·
OSTI ID:4131357
Related Subjects
*GAMMA DOSIMETRY-- GEIGER-MUELLER COUNTERS
*GEIGER-MUELLER COUNTERS-- CALIBRATION
*NEUTRON DOSIMETRY-- PROPORTIONAL COUNTERS
*PROPORTIONAL COUNTERS-- CALIBRATION
COMPARATIVE EVALUATIONS
DOSE RATES
GAMMA RADIATION
KERMA
N46120* --Instrumentation--Radiation Detection Instruments-- Radiation Dosimeters
NEUTRONS
PERFORMANCE
*GEIGER-MUELLER COUNTERS-- CALIBRATION
*NEUTRON DOSIMETRY-- PROPORTIONAL COUNTERS
*PROPORTIONAL COUNTERS-- CALIBRATION
COMPARATIVE EVALUATIONS
DOSE RATES
GAMMA RADIATION
KERMA
N46120* --Instrumentation--Radiation Detection Instruments-- Radiation Dosimeters
NEUTRONS
PERFORMANCE