Gi(Li) detector with separate sensing regions and certain of its applications in neutron activation analysis
Journal Article
·
· Instrum. Exp. Tech. (USSR) (Engl. Transl.), v. 16, no. 4, pp. 1066- 1070
OSTI ID:4343249
Translated from Prib. Tekn. Eksp.; 16: No. 4, 71-75( 1973). A duode spectrometer is described which allows the Compton background to be suppressed by a factor of 4 to 5 in the energy range from 0.3 to 1.5 MeV. The technique of internal summation is used, and the feasibility of its application is investigated. In using a duode spectrometer to determine the scandium content in magnetite samples a threshold sensitivity of 7 x 10/sup -5/% was obtained. (auth)
- Research Organization:
- Inst. of Mineralogy, Geochemistry, and Crystallochemistry of Rare Elements, Moscow
- NSA Number:
- NSA-29-018478
- OSTI ID:
- 4343249
- Journal Information:
- Instrum. Exp. Tech. (USSR) (Engl. Transl.), v. 16, no. 4, pp. 1066- 1070, Journal Name: Instrum. Exp. Tech. (USSR) (Engl. Transl.), v. 16, no. 4, pp. 1066- 1070; ISSN INETA
- Country of Publication:
- Country unknown/Code not available
- Language:
- English
Similar Records
Simple method for measuring the energy equivalent of the noise of semiconductor nuclear radiation detectors
Stabilization of a bore hole gamma spectrometer by means of an injection diode
Estimation of the linearity of the working characteristic of ionization chambers
Journal Article
·
Sun Dec 31 23:00:00 EST 1972
· Instrum. Exp. Tech. (USSR) (Engl. Transl.), v. 16, no. 4, pp. 1071- 1073
·
OSTI ID:4369740
Stabilization of a bore hole gamma spectrometer by means of an injection diode
Journal Article
·
Sun Dec 31 23:00:00 EST 1972
· Instrum. Exp. Tech. (USSR) (Engl. Transl.), v. 16, no. 4, pp. 1027- 1028
·
OSTI ID:4369167
Estimation of the linearity of the working characteristic of ionization chambers
Journal Article
·
Sun Dec 31 23:00:00 EST 1972
· Instrum. Exp. Tech. (USSR) (Engl. Transl.), v. 16, no. 4, pp. 1060- 1062
·
OSTI ID:4323925
Related Subjects
*GAMMA SPECTROMETERS-- LI-DRIFTED GE DETECTORS
*LI-DRIFTED GE DETECTORS
ACTIVATION ANALYSIS
KEV RANGE 100-1000
MEV RANGE 01-10
N40110 --Chemistry--Analytical & Separations Chemistry--Activation & Nuclear Reaction Procedures
N46130* --Instrumentation--Radiation Detection Instruments-- Nuclear Spectroscopic Instrumentation
NEUTRON REACTIONS
SENSITIVITY
*LI-DRIFTED GE DETECTORS
ACTIVATION ANALYSIS
KEV RANGE 100-1000
MEV RANGE 01-10
N40110 --Chemistry--Analytical & Separations Chemistry--Activation & Nuclear Reaction Procedures
N46130* --Instrumentation--Radiation Detection Instruments-- Nuclear Spectroscopic Instrumentation
NEUTRON REACTIONS
SENSITIVITY