RADIAC DOSAGE ALARM
A single instrument, the recycling alarm dosimeter, is proposed for the normal dose and doserate evaluation requirements of a work party entering a radiologically contaminated area. The discussion includes the capabilities and limitations of the recycling dosimeter as a measuring system and a specific review of a hybrid transistor-tube circuit for a field radiac instrument. The instrument discussed has a digital register and is capable of integrating and displaying 1000 r in steps of 0.1 r for doserates from 0.1 r/hr to beyond 500 r/ hr. In addition, a plug connection is provided for operation of the unit as the sensing element of a remote monitoring station to doserates of 10,000 r/hr. (auth)