HEAT TRANSFER AND PRESSURE DROP IN A VERTICAL SQUARE TUBE

Technical Report ·
OSTI ID:4334105
A 1/4-inch square venticai copper tube inside an 8-footlong shell wss found to transfer heat in much the same manner ss a round tube of equal hydraulic diameter. The pressure drop from the bottom to the top of the tube was measured for each operation. Heat flux was uniform throughout the length of the tube up to a steam-to-Freon temperature difference of 20 deg F. The range investigated was approximately from 10 deg to 20 deg F. Data obtained from a single rnn above 20 deg F, indicating that heat flux is not uniform above 20 deg , are in agreement with the results of previous studies. (auth)
Research Organization:
Goodyear Atomic Corp., Portsmouth, Ohio
DOE Contract Number:
AT-(33-2)-1
NSA Number:
NSA-12-013087
OSTI ID:
4334105
Report Number(s):
GAT-236
Country of Publication:
United States
Language:
English

Similar Records

HEAT TRANSFER RATES TO BOILING FREON 114 IN VERTICAL COPPER TUBES
Journal Article · Wed Oct 01 00:00:00 EDT 1958 · Chem. Eng. Progr. · OSTI ID:4326436

BOILING OF FREON-114 IN A THREE-FOOT STRAIGHT TUBE EVAPORATOR
Technical Report · Thu Oct 19 00:00:00 EDT 1961 · OSTI ID:4824539

TWO-PHASE FLOW RATES AND PRESSURE DROPS IN CURVED TUBES
Technical Report · Thu Dec 31 23:00:00 EST 1959 · OSTI ID:4130207