HEAT TRANSFER RATES TO BOILING FREON 114 IN VERTICAL COPPER TUBES
Journal Article
·
· Chem. Eng. Progr.
OSTI ID:4326436
Heat transfer rates from condensing steam to boiling Freon 114 were measured in verticai copper tubes. The rates were uniform along the length of the tube up to a temperature differential of 20 F. Above this temperature difference, 12.5% of the area transferred up to 75% of the total heat. (J.R.D.)