CONTROL OF GASES IN PRIMARY COOLANT DURING FILLING AND COLD PLANT STARTUP

Technical Report ·
OSTI ID:4323978
Estimates are presented of the amounts of gases which will be trapped in the S3G/S4G reactor plant for several cond(tions of cold plant startup. Gencral procedures to be followed during plant filling and warmup to reduce the amounts of gases remaining in the plant after startup are outlined. Specific control measures for each of the several modes of cold plant startup are given. (W.L.H.)
Research Organization:
Knolls Atomic Power Lab., Schenectady, N.Y.
DOE Contract Number:
W-31-109-ENG-52
NSA Number:
NSA-12-002510
OSTI ID:
4323978
Report Number(s):
KAPL-M-SMS-31
Country of Publication:
United States