COMPTON SPECTROMETER USING SUPERPOSITION OF PULSES

Journal Article · · Pribory i Tek. Ekspt.
OSTI ID:4321837
After a brief discussion of the operation of the Compton spectrometer using two scintillation crystals, a description is given of a method which permits a substantial increase of the efficiency of the spectrometer without deterioration in its resolving characteristics. A central and two side crystals are used. The increase in efficiency is obtained by increasing the solid angle of resolution by combination of the pulses from all three crystals. The efficiency of the spectrometer was 1.9%, whereas the efficiency of the normal Compton spectrometer is 0.068%. (J.S.R.)
Research Organization:
Originating Research Org. not identified
NSA Number:
NSA-12-008861
OSTI ID:
4321837
Journal Information:
Pribory i Tek. Ekspt., Journal Name: Pribory i Tek. Ekspt. Vol. Vol: No. 2
Country of Publication:
Country unknown/Code not available
Language:
English

Similar Records

NaI(Tl) SUMMING COMPTON SPECTROMETER
Journal Article · Wed Nov 30 23:00:00 EST 1960 · Rev. Sci. Instr. · OSTI ID:4109735

TWO-CRYSAAL-COMPTON-SPECTROMETER WITH IMPROVED GEOMETRICAL EFFICIENCY
Journal Article · Mon Sep 01 00:00:00 EDT 1958 · Nuclear Instr. · OSTI ID:4292410

SCINTILLATION SPECTROMETER WITH SUMMATION OF PULSES FROM TWO CRYSTALS
Journal Article · Tue Dec 31 23:00:00 EST 1957 · Ceskoslov. casopis pro fysiku · OSTI ID:4144136