MEASUREMENT OF BEAM CURRENT IN THE BEVATRON BY INDUCED VOLTAGES (thesis)

Technical Report ·
DOI:https://doi.org/10.2172/4310029· OSTI ID:4310029

The Bevatron uses a system of electrodes through which the internal proton beam passes in order to continuously measure the magnitude and radial position of the beam. The bunched circulating beam induces a periodic voltage on the electrodes. This signal is amplified and displayed on an oscilloscope and also converted to direct current for operation of a recorder. Two types of electrode systems are used. The first is a large hollow box to provide beam magnitude signals for specialized monitoring and for primary calibration. The second system consists of two sets of smaller electrodes. One set provides beam radial-position information for tracking control, and the other provides beam magnitude information for magnitude control and for general distribution to experimenters associated with the Bevatron. A telemetering radio link is used to relay beam information to those in other areas. Problems associated with handling the beam signal are discussed, and the design principles involved in detection, amplification, and isolation of the signal are described. Calibration techniques, signal distribution facilities, and control features are also given. The systems described are stable and provide the desired information with a minimum of maintenance and operational difficulty. (auth)

Research Organization:
California Univ., Berkeley, CA (US). Radiation Lab.
DOE Contract Number:
W-7405-ENG-48
NSA Number:
NSA-12-014297
OSTI ID:
4310029
Report Number(s):
UCRL-8033
Country of Publication:
United States
Language:
English

Similar Records

BEVATRON INDUCTION-ELECTRODE BEAM-MONITORING SYSTEMS
Technical Report · Tue Oct 01 00:00:00 EDT 1957 · OSTI ID:4317057

ARBITRARY CONTROL OF THE RADIAL POSITION OF THE INTERNAL BEAM OF THE BEVATRON
Technical Report · Thu Dec 31 23:00:00 EST 1959 · OSTI ID:4177805

BEVATRON INDUCTION ELECTRODES