HEAT FLUX AT BURNOUT IN STAGNANT WATER
Technical Report
·
OSTI ID:4309516
The heat flux required to melt vertical tubes of stainless steel, submerged in stagnant water at atmospheric pressure, was measured as the temperature of the ambient water was varied from 10 to 100 deg C. The heat flux in Pcu/ hr-ft/sup 2/ was correlated by (Q/A)/sub Burnout/ = 204,000 + 3,900 DELTA t where DELTA t is tbe difference between the normal boiling point and the temperature of the ambient water. (auth)
- Research Organization:
- Du Pont de Nemours (E.I.) & Co. Savannah River Lab., Augusta, Ga.
- NSA Number:
- NSA-12-006572
- OSTI ID:
- 4309516
- Report Number(s):
- DP-262
- Country of Publication:
- United States
- Language:
- English