Natural convection burnout heat flux limit for control rods

Technical Report ·
DOI:https://doi.org/10.2172/10172829· OSTI ID:10172829
Technical Standard 105-3.05, Safety Circuits, does not require the Septifoil Supply Header Pressure Very Low safety circuit for current charges. This document develops a new requirement for this circuit based on the burnout heat flux of a control rod under natural convective cooling. Specifically, the Septifoil Supply Header Pressure Very Low safety circuit will be required whenever the calculated control rod operating heat flux exceeds 155,000 pcu/ft{sup 2}-hr.