Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

THE ANALYSIS FOR PLUTONIUM BY COUNTING METHODS

Technical Report ·
OSTI ID:4276476

The LaF/sub 3/ method for determining plutonium was investigated and found to give results below 95% of true value. The self-absorption of alphas in Pu sources containing U was measured as a function of U concentration. The absorption reaches 5% when the source contains 500 mu g of U. Hence for solutions of Pu and U better accuracy is obtained if the solution is alpha counted directly and corrected for self-absorption than if the Pu is separated by LaF/sub 3/ precipitation and counted on the La precipitate. The precision decreases as the amount of U on the source increases. (auth)

Research Organization:
Atomic Energy of Canada Ltd. Chalk River Project, Chalk River, Ont.
NSA Number:
NSA-13-011599
OSTI ID:
4276476
Report Number(s):
CEI-58
Country of Publication:
Country unknown/Code not available
Language:
English

Similar Records

RAPID METHOD FOR THE DETERMINATION OF PLUTONIUM IN RADIOACTIVE EFFLUENTS
Journal Article · Sat Dec 31 23:00:00 EST 1960 · Chimie Analytique (Paris) (France) Merged with Method. Phys. Anal. to form Analusis · OSTI ID:4754137

SEPARATION OF PLUTONIUM
Patent · Mon Aug 01 00:00:00 EDT 1960 · OSTI ID:4129298

METHOD OF FORMING PLUTONIUM-BEARING CARRIER PRECIPITATES AND WASHING SAME
Patent · Mon Feb 23 23:00:00 EST 1959 · OSTI ID:4206075