HAZARD SUMMARY REPORT ON THE ARGONNE LOW POWER REACTOR (ALPR)
The over-all design of the Argonne Low Power Reactor is presented. Detailed design data are given as well as information concerning the hydrology, seismology, and meteorology of the building site (NRTS). In addition, a description of the reactor instrumentation and control, mechanical design, heat transfer, and related physics are presented. A full description of the power plant, including the steam and electrical systems, is also given, as well as the operating procedure for both normal and emergency conditions. Over-all reac tor safety is evaluated. Diagrams and graphs are included. (J.R.D.)
- Research Organization:
- Argonne National Lab., Lemont, Ill.
- DOE Contract Number:
- W-31109-ENG-38
- NSA Number:
- NSA-13-005944
- OSTI ID:
- 4273846
- Report Number(s):
- ANL-5744
- Country of Publication:
- United States
- Language:
- English
Similar Records
DESIGN OF THE ARGONNE LOW POWER REACTOR (ALPR)
RADIATION EFFECTS REACTOR SAFEGUARDS
HEATING, VENTILATING, AND AIR CONDITIONING OF THE PLUTONIUM RECYCLE TEST REACTOR (thesis)
Technical Report
·
Mon May 01 00:00:00 EDT 1961
·
OSTI ID:4014868
RADIATION EFFECTS REACTOR SAFEGUARDS
Technical Report
·
Sun Oct 30 23:00:00 EST 1960
·
OSTI ID:4219253
HEATING, VENTILATING, AND AIR CONDITIONING OF THE PLUTONIUM RECYCLE TEST REACTOR (thesis)
Technical Report
·
Thu Dec 31 23:00:00 EST 1959
·
OSTI ID:4156773