Title: HAZARD SUMMARY REPORT ON THE ARGONNE LOW POWER REACTOR (ALPR)

Technical Report ·
DOI:https://doi.org/10.2172/4273846· OSTI ID:4273846

The over-all design of the Argonne Low Power Reactor is presented. Detailed design data are given as well as information concerning the hydrology, seismology, and meteorology of the building site (NRTS). In addition, a description of the reactor instrumentation and control, mechanical design, heat transfer, and related physics are presented. A full description of the power plant, including the steam and electrical systems, is also given, as well as the operating procedure for both normal and emergency conditions. Over-all reac tor safety is evaluated. Diagrams and graphs are included. (J.R.D.)

Research Organization:
Argonne National Lab., Lemont, Ill.
DOE Contract Number:
W-31-109-ENG-38
NSA Number:
NSA-13-005944
OSTI ID:
4273846
Report Number(s):
ANL-5744
Resource Relation:
Other Information: Orig. Receipt Date: 31-DEC-59
Country of Publication:
United States
Language:
English