FLOW DECAY AFTER AN ELECTRICAL POWER OUTAGE IN THE PRTR
Technical Report
·
OSTI ID:4268428
The effects of electrical power loss to the PRTR primary coolant pump were studied. It was concluded that the flow provided by the stored kinetic energy and natural convection is adequate to suppress bulk boiling in the prfmary coolant from heat produced by the hot channel. It is recommended that the pumps be removed from the line affer 2 minutes; however, natural convection suppresses boiling after 45 seconds following electrical outage. (J.R. D.)