Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

PRTR PRIMARY PUMP FLYWHEEL ANALYSIS

Technical Report ·
OSTI ID:4159324
The ability of a prototype PRTR primary pump equipped with a flywheel (1185 lb-ft/sup 2/ moment of inertia) to maintain adequate coolant flow, in a total electric power failure, until natural convection flow became sufficient was investigated. Experiments showed that the flywheel decay times varied from one to three minutes; and analytical study showed that mechanical friction in the pump seals can produce the variation. In all instances, the flywheel maintained adequate flow until after convective flow would have started (D.C.W.)
Research Organization:
General Electric Co. Hanford Atomic Products Operation, Richland, Wash.
DOE Contract Number:
AT(45-1)-1350
NSA Number:
NSA-18-001296
OSTI ID:
4159324
Report Number(s):
HW-63401
Country of Publication:
United States
Language:
English

Similar Records

THE EFFECT OF TEMPERATURE ON FLOW AND FLOW INDICATION IN THE PRIMARY COOLANT SYSTEM OF THE PRTR
Technical Report · Sun Feb 09 23:00:00 EST 1958 · OSTI ID:4282805

PLUTONIUM RECYCLE TEST REACTOR PRIMARY COOLANT PUMPS
Technical Report · Mon Jul 01 00:00:00 EDT 1963 · OSTI ID:4674069

FLOW DECAY AFTER AN ELECTRICAL POWER OUTAGE IN THE PRTR