Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

THE "THORIN" COLORIMETRIC METHOD FOR THORIUM DETERMINATION: EFFECT OF SOME COMMON IONS, AND METHODS FOR OVERCOMING INTERFERENCES

Technical Report ·
OSTI ID:4248384
The effect of a number of common ions on the Thorin colorimetric method for Th determination were investigated. A comparison was carried out on the use of the two reducing agents, ascorbic acid and hydroxylamine hydrochloride, for overcoming the interference of Fe and Ce. Mo caused low Th assays in the presence of ascorbic acids whereas this effect was not found with hydroxylamine hydrochloride presents or in the absence of a reducing agent. Ti caused low Th assays under any conditions tried and a very low tolerance limit must be set for this ion. Zr caused high Th assays under normal conditions, but its effect varied with the form in which it was added, and appeared to be enhanced by the presence of Th. By using mesotartaric acid as a masking agent for Zr approximately 5 mg of Zr could be tolerated in a final 25 mi volume taken for the colorimetric finish. In the absence of Zr, mesotartaric acid is not required and a final volume of 250 ml is usecl. (auth)
Research Organization:
Canada. Dept. of Mines and Technical Surveys. Mines Branch
NSA Number:
NSA-13-014237
OSTI ID:
4248384
Report Number(s):
NP-7538; R-34
Country of Publication:
Country unknown/Code not available
Language:
English

Similar Records

REMOVAL OF INTERFERENCES IN ABSORPTIOMETRIC DETERMINATION OF BISMUTH WITH THORIN
Journal Article · Sun Sep 01 00:00:00 EDT 1963 · Analytica Chimica Acta (Netherlands) · OSTI ID:4645288

COLORIMETRIC DETERMINATION OF URANIUM(IV)
Technical Report · Mon May 01 00:00:00 EDT 1961 · OSTI ID:4009027

COLORIMETRIC DETERMINATION OF NEPTUNIUM WITH THORIN
Journal Article · Thu Jun 01 00:00:00 EDT 1961 · Analytical Chemistry (U.S.) Formerly Ind. Eng. Chem., Anal. Ed. · OSTI ID:4001752