DETECTOR FOR SLOW NEUTRONS

Journal Article · · Chechoslov. J. Phys.
OSTI ID:4233746
A scintillation countor is proposed for slow neutrons, The counter is obtained by sintering ZnS (Ag) and B/sub 2/O/sub 3/ The experimentally-obtained optimum value of the ratio ZnS (Ag)/B, which is approximately equal to 9; 1, makes it possible to obtain a scintillator of large dimensions wlth a thickness from 0,75 to 1 mm with sufficiently high efficiency with respect to registration of thermal neuirons (25%). The detector cddn operate with a strong background of gamma rays because of its different sensitivity to gamma rays (from 10/sup -4/ to 10/sup -8%/) and thermal neutrons (from 10 to 5% respectively). The counter has a resolution on the order of 10/sup -7/ seconds and a sufficiently good stability. (auth)