THE STOPPING-POWER CORRECTION FOR GRAPHITE CAVITY-CHAMBERS USED WITH 2 mV X- RAYS

Journal Article · · Phys. in Med. Biol.

A precise comparison has been made of the relative behavior of a typical graphite cavity ionization chamber and an identical chamber made from an alloy of lithium and magnesium (average number of electrons per atom, 8.244). An examination has been made of the difficulties involved in determining precisely a stopping-power correction for the NPL graphite cavity iorization chambers in view of the existing uncertainties in the present state of knowledge. It is concluded that the present arbitrary total correction of +3% applied to the readings of the graphite chambers for wall absorption, lack of electronic equilibrium and stopping power cannot be seriously in error. (auth)

Research Organization:
National Physical Lab., Teddington, Middx, Eng.
NSA Number:
NSA-14-003685
OSTI ID:
4227680
Journal Information:
Phys. in Med. Biol., Journal Name: Phys. in Med. Biol. Vol. Vol: 4
Country of Publication:
Country unknown/Code not available
Language:
English

Similar Records

A STUDY OF CAVITY ION CHAMBERS FOR USE WITH 2 mV X-RAWS: EQUILIBRIUM WALL THICKNESS: WALL-ABSORPTION CORRECTION
Journal Article · Tue Mar 31 23:00:00 EST 1959 · Phys. in Med. Biol. · OSTI ID:4212847

The replacement correction factor for the BIPM flat cavity ion chamber and the value of W/e
Journal Article · Wed Oct 15 00:00:00 EDT 2008 · Medical Physics · OSTI ID:22095213

Measurement of Stopping-Power Ratio for Cavity Ionization Chambers
Journal Article · Fri Nov 10 23:00:00 EST 1961 · Nature (London) · OSTI ID:4811585