THE STOPPING-POWER CORRECTION FOR GRAPHITE CAVITY-CHAMBERS USED WITH 2 mV X- RAYS
                            Journal Article
                            ·
                            
                            · Phys. in Med. Biol.
                            
                        
                    A precise comparison has been made of the relative behavior of a typical graphite cavity ionization chamber and an identical chamber made from an alloy of lithium and magnesium (average number of electrons per atom, 8.244). An examination has been made of the difficulties involved in determining precisely a stopping-power correction for the NPL graphite cavity iorization chambers in view of the existing uncertainties in the present state of knowledge. It is concluded that the present arbitrary total correction of +3% applied to the readings of the graphite chambers for wall absorption, lack of electronic equilibrium and stopping power cannot be seriously in error. (auth)
- Research Organization:
- National Physical Lab., Teddington, Middx, Eng.
- NSA Number:
- NSA-14-003685
- OSTI ID:
- 4227680
- Journal Information:
- Phys. in Med. Biol., Journal Name: Phys. in Med. Biol. Vol. Vol: 4
- Country of Publication:
- Country unknown/Code not available
- Language:
- English
Similar Records
                                
                                
                                    
                                        
                                        A STUDY OF CAVITY ION CHAMBERS FOR USE WITH 2 mV X-RAWS: EQUILIBRIUM WALL THICKNESS: WALL-ABSORPTION CORRECTION
                                        
The replacement correction factor for the BIPM flat cavity ion chamber and the value of W/e
Measurement of Stopping-Power Ratio for Cavity Ionization Chambers
                        
                                            Journal Article
                                            ·
                                            Tue Mar 31 23:00:00 EST 1959
                                            · Phys. in Med. Biol.
                                            ·
                                            OSTI ID:4212847
                                        
                                        
                                        
                                    
                                
                                    
                                        The replacement correction factor for the BIPM flat cavity ion chamber and the value of W/e
                                            Journal Article
                                            ·
                                            Wed Oct 15 00:00:00 EDT 2008
                                            · Medical Physics
                                            ·
                                            OSTI ID:22095213
                                        
                                        
                                        
                                    
                                
                                    
                                        Measurement of Stopping-Power Ratio for Cavity Ionization Chambers
                                            Journal Article
                                            ·
                                            Fri Nov 10 23:00:00 EST 1961
                                            · Nature (London)
                                            ·
                                            OSTI ID:4811585