Tests are described to determine the amount of entrained moisture occurring in the steam of the Pathfinder Power Plant as design parameters were varied. It was found that the height of the moisture separator and the velocity of the steam should be adjusted so that the permissible steam velocity for the particular height is not exceeded. If this is done, the amount of moisture entering the separator should be less than 1%, an amount of moisture that should not be difficult to remove with moisture separators. (J.R.D.)
Research Organization:
Allis-Chalmers Mfg. Co. Atomic Energy Div., Milwaukee
NSA Number:
NSA-14-004115
OSTI ID:
4208114
Report Number(s):
ACNP-5921
Country of Publication:
United States
Language:
English

Similar Records

REMOVAL OF ENTRAINED MOISTURE FROM STEAM USING NATURAL SEPARATION AND MECHANICAL DRYERS. Pathfinder Atomic Power Plant, Final Summary Report
Technical Report · Fri Apr 14 23:00:00 EST 1961 · OSTI ID:4046544

PATHFINDER ATOMIC POWER PLANT STEAM SEPARATOR DEVELOPMENT
Technical Report · Fri Jun 15 00:00:00 EDT 1962 · OSTI ID:4785350

The Moisture Separation in BWR
Journal Article · Sat Dec 31 23:00:00 EST 1960 · Nippon Genshiryoku Gakkai-Shi · OSTI ID:4819043